1 – Exemptions / special considerations | ||
| a) | Flexibility can be adopted in applying these regulations to Listed Buildings, buildings in Conservation Areas and buildings with architectural/ historic merit. Building Control will discuss with Conservation team. |
2 – Extensions – 3 ways of proving compliance; | ||
| a) | Meet min. fabric standards e.g. wall (0.28, windows 1.6) and limit windows etc. |
| b) | Area weighted u-value calculation – see our heat loss calculator. |
| c) | Whole dwelling calculation using SAP 2009. |
In all cases heating and lighting must satisfy minimum requirements and limiting u-values must be complied with to prevent risk of condensation – 0.7 walls and 0.35 roofs. |
3 – Conservatories / Porches | ||
| a) | Not exempt if heating system is extended from dwelling into the conservatory. |
| b) | If not exempt for any reason, thermal separation required, independent heating controls, all elements to meet min standards, but no limit on glazing. |
| c) | No mention made of substantially glazed extensions, but considered reasonable to treat as non-exempt conservatory / porch. |
4 – Change of use / change of energy status | ||
| a) | Controlled services / fittings to meet new standards. |
| b) | Ensure area of windows not excessive. |
| c) | All new elements to meet new standards. |
| d) | Replace windows/ doors if >3.3 |
| e) | Upgrade retained / renovated thermal elements as necessary. |
Alternatively, use SAP 2009 to prove compliance. In addition, Energy Performance Certificate required if building will contain a greater or fewer number of parts for separate use. |
5 – Controlled fittings | ||
| a) | Windows – meet new standards (1.6 or WER band C, doors 1.8), draught proof and provide insulated cavity closers. |
| b) | If new window opening provided, ensure total does not exceed 25% or other measures to be adopted. |
6 – Fixed Building Services (e.g. Heating/ hot water systems, Lighting) | ||
| a) | If extended or provided – follow guidance in DBSC guide. |
| b) | Replacing – ensure no less efficient than before. |
| c) | Commissioning certificates required for heating and hot water systems before completion certificate can be issued. |
7 – User operating information | ||
| a) | Operating and maintenance instructions to be given to user. |
8 – Continuity of insulation and air-tightness | ||
| a) | Must be ensured – adopt accredited construction details. |
9 – Renovation of thermal elements | ||
| a) | Details provided of when elements must be improved when being renovated (50% of element, 25% of total building). |
| b) | Practical examples provided in Appendix A. |
10 – Consequential improvements | ||
| a) | Required when extending or providing fixed building services to very large dwellings (>1000m²). |